Chiller, Boiler & Cooling Tower Service in Greensboro, High Point & Winston-Salem

Central plant work is where downtime gets expensive. SBS-NC self-performs chiller, boiler, and tower maintenance and repair across the Triad — same crew, same standard, since 1992.

Schedule a Plant Walk-Through See Scope of Work

The short answer

SBS-NC, LLC services commercial chillers, boilers, and cooling towers in Greensboro, High Point, and Winston-Salem, NC, and throughout the Triad. Based in High Point since 1992, we self-perform annual inspections, seasonal startup and shutdown, tube and coil cleaning, burner and combustion tuning, tower cleaning and rebuilds, pump and VFD repair, refrigerant management, and plant controls — on air-cooled and water-cooled chillers, hot water and steam boilers, and induced- and forced-draft towers, including equipment we didn't install. Contract customers get 24/7 emergency dispatch. Call (336) 234-4979 to schedule a plant walk-through.

An SBS-NC technician servicing a Daikin air-cooled chiller on a rooftop at High Point University
On the job — campus chiller plant

Air-cooled chiller service at High Point University — one of the campus plants we maintain. Compressors, coils, controls, and refrigerant checked by our own technicians, then logged so next year's numbers mean something.

Scope of Work

Three systems, one contractor.

Chillers

Air-cooled and water-cooled machines — scroll, screw, and centrifugal.

Annual inspection & seasonal startup
Condenser tube cleaning & eddy current coordination
Compressor, oil, and refrigerant service
Leak repair & refrigerant management
Controls, sensors, and staging
Evaporator & approach troubleshooting

Boilers

Hot water and steam, gas-fired and condensing.

Combustion analysis & burner tuning
Low water cutoff & safety testing
Relief valve & control calibration
Heat exchanger & flue inspection
Pump, valve, and expansion tank service
Scale & corrosion prevention

Cooling Towers

Induced and forced draft, all major brands and configurations.

Cleaning, disinfection & basin service
Fill & drift eliminator replacement
Gearbox, shaft, and motor service
Fan, belt drive, and bearing work
Float, makeup valve, and sump repair
Water treatment coordination

Plus the rest of the plant

Primary and secondary pumps, VFDs and motors, air handlers and coils, valves and actuators, piping and insulation repair, and chilled- and hot-water sequencing at the controls level. A chiller that short-cycles is often a pump or a control problem, so we look at the plant as one system.

Warning Signs

Call before it becomes a shutdown.

Rising approach temperatures

Chilled water approach creeping up usually means fouled tubes, a low charge, or airflow trouble at the condenser.

Chiller short-cycling or nuisance trips

Repeated low-pressure or high-head trips point at flow, control, or refrigerant problems that get worse fast.

Scale, slime, or white deposits

Water chemistry is off. Left alone it costs efficiency first, then tubes and fill.

Tower fan noise or vibration

Gearbox, bearing, or shaft alignment issues — cheap now, catastrophic if the fan lets go.

Boiler soot, sooting, or yellow flame

Combustion is out of tune. That's wasted fuel and a safety concern worth same-week attention.

Cycling on low water cutoff

A makeup, air-elimination, or leak problem — and a code-critical safety device you don't want exercising itself.

Basin overflow or constant makeup

Failed float, cracked basin, or excess blowdown quietly running your water bill up.

Loss of capacity in shoulder season

A plant that can't hold setpoint in mild weather won't hold it in August. Diagnose it while the load is low.

Where We Work

Central plant service across the Triad.

Our shop is in High Point, which puts a technician inside thirty minutes of most Triad mechanical rooms.

High Point, NC

Home base. Chiller and boiler plants at universities, furniture manufacturing, warehouses, and multi-tenant properties — including long-running campus work.

Greensboro, NC →

Office towers, medical and professional buildings, distribution centers, and process cooling loads on the east side of the Triad.

Winston-Salem, NC →

Downtown offices, research and lab space, schools, and industrial plants where tower and chiller uptime drives operations.

Also serving Kernersville, Thomasville, Archdale, Burlington, Lexington, Asheboro, and Greater Charlotte — plus five more southeastern states.

Plant Maintenance

Central plants belong on a program.

A rooftop unit failing is an inconvenience. A chiller failing in July, or a boiler failing in January, stops the building. Scheduled plant maintenance is the cheapest insurance in the mechanical room — and it gives you documented equipment history when it's time to defend a capital request.

See maintenance programs

Seasonal startup & shutdown

Chillers commissioned before cooling season, boilers before heating season, towers cleaned at both ends.

Trending & logs

Approach temps, pressures, amp draws, and water chemistry tracked visit over visit so drift shows up early.

24/7 priority dispatch

Contract customers reach dispatch any hour — the reason most plant customers sign in the first place.

Common Questions

Chiller, boiler & tower FAQ.

Does SBS-NC service chillers in Greensboro, High Point, and Winston-Salem?
Yes. We're based in High Point, NC and self-perform chiller, boiler, and cooling tower service throughout Greensboro, High Point, Winston-Salem, and the surrounding Triad, including Kernersville, Thomasville, Burlington, and Archdale.
How often should a commercial chiller be serviced?
A commercial chiller should get a full annual inspection before cooling season plus quarterly operational checks. Water-cooled machines also need condenser tube cleaning and water treatment monitoring, and oil and refrigerant analysis is recommended annually on centrifugal and screw chillers.
How often should a cooling tower be cleaned?
Towers should be inspected monthly during operation and fully cleaned and disinfected at least twice a year, typically at startup and shutdown. Towers in dusty or high-pollen environments, or serving critical process loads, need more frequent basin cleaning and fill inspection.
What maintenance do commercial boilers need?
Annual combustion analysis and burner tuning, low water cutoff testing, safety and relief valve verification, flue and heat exchanger inspection, control calibration, and water treatment monitoring to prevent scale and corrosion.
Can SBS-NC take over a plant another contractor maintained?
Yes. We start with a full walk-through and equipment inventory, document current condition and deficiencies, then propose a maintenance scope and schedule. We service equipment we didn't install and are trained on all major chiller, boiler, and tower brands.
Do you offer emergency chiller and boiler service?
Yes. Maintenance contract customers receive 24/7 emergency response and priority dispatch — which matters most for plants serving manufacturing, healthcare, data, and campus loads where an outage stops operations.
Do you handle water treatment for chillers and towers?
We coordinate water treatment as part of a central plant maintenance program, monitoring conductivity, scale, and biological control so condenser tubes and tower fill stay clean and heat transfer stays efficient.

Let's walk your mechanical room.

We'll inventory the plant, document condition, and price a scope — Greensboro, High Point, or Winston-Salem.

Call (336) 234-4979 Something down now? Repairs & diagnostics