Commercial HVAC preventative maintenance is priced per unit, per visit. SBS-NC publishes its rates: $200 for the first rooftop unit or split system at a site and $149 for each additional unit, or $149 for every unit at a site with four or more. Multiply the per-visit total by the number of visits a year (two, four, or twelve) and you have the annual cost. Chillers, boilers, cooling towers, and pumps are quoted per machine after a walk-through. The rest of this guide shows the math, worked examples from one unit to a multi-site portfolio, what the price includes, and how to compare one maintenance quote with another.
SBS-NC's published maintenance pricing
| Equipment | Price per visit | Notes |
|---|---|---|
| First rooftop unit (RTU) or split system at a site | $200 | Sites with one to three units |
| Each additional RTU or split system at the same site | $149 | Second and third unit |
| Every unit at a site with four or more | $149 | Replaces the $200 first-unit price |
| VRF systems, exhaust fans, and make-up air units | Priced separately | Included in a Quick Quote estimate |
| Chillers, boilers, cooling towers, and pumps | Quoted per machine | After a plant walk-through |
| Trip and diagnostic fee on covered equipment | Waived | For maintenance contract customers |
Budgetary pricing. Program pricing also depends on equipment type and site access, and the actual price may be lower or higher; multi-site and contract pricing is available on request.
The formula
- Per-visit price at a site with one to three units: $200 + $149 × (units − 1)
- Per-visit price at a site with four or more units: $149 × units
- Annual cost: per-visit price × visits per year (2 for semi-annual, 4 for quarterly, 12 for monthly)
The four-unit break matters more than it looks. Three units are $498 a visit and four units are $596, so the fourth unit adds $98.
Worked examples: annual commercial HVAC maintenance cost
| Units at the site | Per visit | Semi-annual (2 visits) | Quarterly (4 visits) | Monthly (12 visits) |
|---|---|---|---|---|
| 1 unit | $200 | $400 | $800 | $2,400 |
| 2 units | $349 | $698 | $1,396 | $4,188 |
| 3 units | $498 | $996 | $1,992 | $5,976 |
| 4 units | $596 | $1,192 | $2,384 | $7,152 |
| 6 units | $894 | $1,788 | $3,576 | $10,728 |
| 8 units | $1,192 | $2,384 | $4,768 | $14,304 |
| 12 units | $1,788 | $3,576 | $7,152 | $21,456 |
| 20 units | $2,980 | $5,960 | $11,920 | $35,760 |
| 40 units | $5,960 | $11,920 | $23,840 | $71,520 |
Which program fits depends on how hard the equipment runs. Semi-annual suits offices, small retail, and light-use equipment. Quarterly is the standard for shopping centers, schools, apartment communities, and multi-tenant buildings. Monthly is for restaurants, manufacturing, and anything that runs hard all year. The program comparison on our preventative maintenance page shows what each one includes.
Multi-site portfolios: the price is per site
The unit tiers apply at each site, not across the portfolio, so a chain of small stores and a single large building with the same total unit count price differently. One round is one visit to every site.
| Portfolio | Per site, per visit | One round of all sites | Semi-annual | Quarterly |
|---|---|---|---|---|
| 5 stores, 2 units each | $349 | $1,745 | $3,490 | $6,980 |
| 6 stores, 3 units each | $498 | $2,988 | $5,976 | $11,952 |
| 10 stores, 4 units each | $596 | $5,960 | $11,920 | $23,840 |
| 25 stores, 2 units each | $349 | $8,725 | $17,450 | $34,900 |
One contract can cover sites in several markets with the same scope, invoice format, and reporting. See the financial case for multi-site HVAC preventative maintenance for how a portfolio program is built, and retail and multi-site programs in Charlotte for an example market.
What the price includes
- Every program: filter replacement, a full inspection of each unit, a written report per unit, 24/7 emergency response, and the trip and diagnostic fee waived on covered equipment.
- Quarterly and monthly programs add: condenser and evaporator coil cleaning and priority dispatch for service calls.
- Monthly programs add: monthly filter service plus asset tracking and lifecycle reporting.
The task list a visit should cover, by season and by equipment type, is in our commercial HVAC preventative maintenance checklist. A price only means something next to a task list.
What the price does not include
Repairs and replacement parts. Anything found on a maintenance visit is written up on that unit's report and quoted before work begins, so nothing is billed that was not approved. Central plant equipment is also outside the per-unit rate: it is quoted per machine, as covered below. How diagnostics and repair quotes work is on our commercial HVAC repair page.
What moves the price of a maintenance contract
- Units per site. Sites with one to three units pay $200 for the first unit and $149 for the rest; once a site has four or more units, every unit is $149.
- Visits per year. The biggest lever. Quarterly costs twice what semi-annual does, and it is still the right answer for equipment that loads filters and coils quickly.
- Equipment type. Rooftop units and split systems are on the per-unit rate. VRF, exhaust, and make-up air price separately, and chillers, boilers, towers, and pumps are quoted per machine.
- Site access. Roof access, lifts, security escorts, and after-hours-only buildings change how long a visit takes.
- How many sites. Multi-site and contract pricing is available on request.
Why chillers, boilers, and cooling towers are quoted per machine
A rooftop unit's maintenance visit is predictable enough to price by the unit. A central plant is not. A chiller's annual work can include oil analysis, tube brushing, and eddy-current testing every few years; a boiler's includes combustion analysis and safety control testing; a cooling tower's includes cleaning, mechanical checks, and coordination with the water treatment program. The type, size, age, and condition of each machine set the hours, so we walk the plant and quote each machine. The task lists are on our commercial chiller service and boiler and cooling tower service pages.
Is preventative maintenance worth the cost?
The U.S. Department of Energy's Operations and Maintenance Best Practices Guide estimates that a preventive maintenance program costs 12 to 18 percent less than a purely reactive, run-to-failure approach. That figure is general, not a promise about any one building, and it does not count what downtime costs a store, a clinic, or a production line. The costs it is counting are the ones in the consequences of putting off commercial HVAC repairs: higher energy use from dirty coils and failed economizers, shorter equipment life, and repairs done at emergency timing instead of planned timing.
How to compare maintenance quotes
- Same unit count, same number of visits. A quote that looks cheaper is often for fewer visits.
- The task list in writing. Ask what is done on each unit at each visit and compare it with a checklist.
- Filters and coil cleaning. Ask whether filters are included and how often coils are cleaned.
- The report. One entry per unit with readings, not one line for the building.
- How repairs are handled. Quoted before work begins, with the diagnostic fee waived or not.
- Emergency response. Whether contract customers get after-hours dispatch and priority.
- Who does the work. The contractor's own technicians or a subcontractor. See why self-performing contractors outperform brokers.
Get your own number
If you keep an equipment list, the Quick Quote tool turns it into a budgetary annual range in your browser, by site and by program. For a firm price, including central plant equipment, call (336) 307-4218 or request a walk-through. The program itself is described on our commercial HVAC preventative maintenance page.